DelVal · Authorised dealer
DelVal Series 83 Limit Switch Box
The DelVal Series 83 is a limit switch box, or valve position monitor, that mounts on a quarter-turn actuator on the NAMUR interface and signals valve position, with IP65 as standard and IP67 available.
Authorised DelVal dealer · Mumbai · Valve stockists since 1969

- Weatherproof
- IP65 as standard / IP67 available
- Mounting
- NAMUR
- Temperature range
- Standard -20°C to 80°C (-4°F to 176°F)
- Switch type
- Honeywell SPDT mechanical switches as standard
Overview
A limit switch box sits on top of an automated valve and tells the control system whether the valve has actually reached open or closed. The Series 83 has a die cast aluminium body with a powder coated finish and a polycarbonate dome, so the position can also be read by eye at the valve.
Honeywell SPDT mechanical switches are fitted as standard, with inductive and proximity switch options for other signal needs. Two ½" NPT conduit entries are standard, and M20x1.5 or ¾" NPT entries can be specified. The shaft is SS316, the hardware SS304 and the circuit board glass epoxy. An explosion proof version is available on request, and the series carries an ATEX explosion proof certificate and a SIL3 certificate.
Specifications
| Body type | Limit switch box |
|---|---|
| Body | Aluminium die cast powder coated body, polycarbonate dome |
| Weatherproof | IP65 as standard / IP67 available |
| Conduit entries | (2 qty) ½" NPT as standard; M20x1.5 and ¾" NPT options available |
| Mounting | NAMUR |
| Temperature range | Standard -20°C to 80°C (-4°F to 176°F) |
| Switch type | Honeywell SPDT mechanical switches as standard; other inductive and proximity switch options available |
| Explosion proof version | Available on request |
| Top cover | Aluminium |
| Dome indicator | ABS plastic |
| Shaft | SS316 |
| Hardware | SS304 |
| PCB | Glass epoxy |
| Mounting standard | NAMUR VDI/VDE 3845 |
Technical specifications
Full technical data for the DelVal Series 83 Limit Switch Box, from DelVal's published data. Open a section below for the full tables, or download the UEC datasheet.
Dimensions and weights
Metal mounting bracket (mm)
| Actuator size | A | B | C | D |
|---|---|---|---|---|
| 045 TO 100 | 60 | 45 | 80 | 90 |
| 115 TO 200 | 85 | 55 | 130 | 145 |
Metal mounting bracket (inch)
| Actuator size | A | B | C | D |
|---|---|---|---|---|
| 045 TO 100 | 2.36 | 1.77 | 3.15 | 3.54 |
| 115 TO 200 | 3.35 | 2.17 | 5.12 | 5.71 |
Note : All dimensions given in brackets are in INCHES
Key to dimension letters
- A
- Bracket width across the two legs
- B
- Overall bracket height
- C
- Centre distance of the outer mounting holes
- D
- Overall bracket length
Limit switch box (mm, inch in brackets)
- Width left of centreline
- 69.5 (2.74)
- Width right of centreline
- 54.5 (2.15)
- Height, top of dome to underside of body
- 110.5 (4.35)
- Overall height
- 143.5 (5.65)
- Shaft projection below base
- 29 (1.14)
- Shaft end step length
- 6 (0.24)
- Shaft diameter
- Ø9 (Ø0.35)
- Shaft tip length
- 4 (0.15)
- Body width (bottom view)
- 119 (4.69)
- Mounting holes
- M5x8(0.31)DEEP TAPPED HOLES 4 Nos. ON 50 (1.97) PCD
- Shaft tip width (bottom view)
- 4 (0.15)
- Conduit entry
- 1/2″ NPT PLACES
Materials of construction
Parts list
| Sr. no. | Component description | Material / make | Qty |
|---|---|---|---|
| 01 | BODY | ALUMINUM | 1 |
| 02 | TOP COVER | ALUMINUM | 1 |
| 03 | DOME COVER | POLYCARBONATE | 1 |
| 04 | DOME INDICATOR | ABS PLASTIC | 1 |
| 05 | SHAFT | SS 316 | 1 |
| 06 | CAM | ABS PLASTIC | 2 |
| 07 | CAM GEAR | DELRIN | 2 |
| 08 | SPRING | SPRING STEEL | 1 |
| 09 | LIMIT SWITCH | HONEYWELL | 2 |
| 10 | PCB | GLASS EPOXY | 1 |
Electrical data
Switch and sensor options
| Switch type | Switch make | Switch model | Rating | Qty |
|---|---|---|---|---|
| SPDT | HONEYWELL | V15T16-EZ200A05 | 16 Amps, 125 or 250 V AC, 220 V DC NO / NC | 2 |
| INDUCTIVE SENSOR | – | – | – | – |
| RECTANGULAR | P & F | NJ2-V3-N | 8V DC, 3 mA, Namur, NC | 2 |
| RECTANGULAR | P & F | NBB3-V3-Z4 | 5 - 60 V DC, 100 mA, 2 Wire, NO | 2 |
| CYLINDRICAL | P & F | NJ2-12-GM-N | 8V DC, Namur, NC | 2 |
| CYLINDRICAL | P & F | NCB2-12GM35-NO | 8V DC, 3 mA, Namur, NC | 2 |
| CYLINDRICAL | P & F | NCB4-12GM40-Z0 | 5 - 60 V DC, 100 mA, 2 Wire, NO | 2 |
| CYLINDRICAL | P & F | NCN4-12GM35-NO | 8V DC, 3 mA, Namur, NC | 2 |
| SLOTTED | P & F | SLOTTED SJ 3.5 N | 8V DC, 3 mA, Namur, NC | 2 |
Standards and specifications
Features and specifications
- Feature
- Aluminum die cast powder coated body
- Feature
- High corrosion resistance
- Feature
- Polycarbonate dome
- Feature
- Fully adjustable spring loaded cams for easy setting
- Feature
- Special printed circuit board to eliminate all wiring from the switch elements to terminals
- Feature
- Protection against short circuit
- Feature
- (2) 1/2 ” conduit entries
- Feature
- Namur mounting as standard
- Feature
- Weather proof IP 65 / IP 67
- Temperature range
- -20 °C to 80 °C (-4 °F to 176 °F)
- Cable Entry
- 1/2” NPT (2)
- Cable Entry
- M20 x 1.5 (2 by adapter)
- Cable Entry
- 3/4” ET (2 by adapter)
- Brackets
- Open (Metal)
- Body Material
- Aluminum
Design features
- Powder coated die cast aluminium body
- Polycarbonate dome for local position indication
- IP65 as standard, IP67 on request
- Two ½" NPT conduit entries, with M20x1.5 and ¾" NPT options
- Honeywell SPDT mechanical switches, inductive and proximity options
- NAMUR mounting
- Explosion proof version available on request
Where it is used
Position monitors belong on any automated valve whose state the control system must confirm rather than assume. Typical cases are interlocked batch sequences, tank farm transfer routes, firewater and shut-down valves, filter backwash sequences and dosing lines where a valve left part open causes product loss. Pharmaceutical, chemical, refinery, petrochemical, oil and gas, power, water, food and beverage, paper and mining plants all fit them. The Series 83 can be specified with an explosion proof enclosure for classified areas, and DelVal's SIL3 certificate supports its use on safety-related valves when SIL-certified sensors are fitted and the loop is designed for it. Instrumentation engineers and control panel integrators wiring valve feedback into a PLC or DCS will find the standard SPDT switches simple to connect.
- Pharmaceuticals
- Chemicals
- Refining
- Petrochemicals
- Oil and gas
- Power generation
- Water and wastewater
- Food and beverage
- Pulp and paper
- Mining
- Tank terminals
- OEM skids
Before you order
Choose the switch to suit the control system
Mechanical SPDT switches suit simple open and closed contacts wired into a PLC input card or relay panel. Inductive or proximity sensors are often chosen where there are many cycles or where the control system expects a sensor input. State the signal type your control system takes so that the right switch option is quoted.
Specify enclosure and cable entry
IP65 is standard and IP67 is available where the box may be flooded or temporarily immersed. In a hazardous area, ask for the explosion proof version and give the zone classification. Confirm the cable gland thread your site uses: ½" NPT is standard, with M20x1.5 and ¾" NPT as options.
Check the ambient temperature
The standard range is -20°C to 80°C. If the valve sits near hot equipment such as steam lines or furnaces, or in cold storage, check the expected ambient against that range and raise it in the enquiry before the switch box is ordered.
Buy DelVal Series 83 in Mumbai and across India
Buy the DelVal Series 83 Limit Switch Box from UEC, an authorised DelVal distributor, dealer and valve stockist in Mumbai that supplies across India.
Share the size, rating, materials and quantity, and UEC sends the DelVal Series 83 price as a quotation, with despatch within India or export packing on request.
Certifications and approvals
- ATEX explosion proof (limit switch box)
- SIL3 (Series 83 valve position monitor)
How to order from UEC
Send the details
Tell us the DelVal series, size, pressure class, body, disc or ball and seat materials, end connection, the medium and its temperature, the quantity and whether you need an actuator.
We confirm and quote
UEC matches your requirement to the right DelVal series and sends a quotation. Ask for current stock of the size you need.
Supply and documents
Orders are supplied from Mumbai across India and worldwide, with the manufacturer's test certificates. Third-party inspection can be arranged when the order requires it.
Questions buyers ask
What IP rating does the DelVal Series 83 have?
The Series 83 is IP65 as standard, and IP67 is available. Mention IP67 at the enquiry stage if the switch box may be flooded or temporarily immersed, since the enclosure option is set when the unit is ordered.
Which cable entries does the Series 83 have?
It has two ½" NPT conduit entries as standard. M20x1.5 and ¾" NPT entries are available as options, which avoids thread adaptors when your site uses metric glands. State the gland thread with the order.
Is there an explosion proof Series 83?
Yes, an explosion proof version is available on request, and it carries an ATEX explosion proof certificate. Give the area classification with your enquiry so the correct version is supplied, and match the actuator and solenoid valve to the same zone.
Will the Series 83 fit my existing actuator?
The Series 83 uses NAMUR mounting to VDI/VDE 3845, the common accessory interface on pneumatic quarter-turn actuators, including the DelVal Series 21. Share the actuator make and model and UEC will confirm the mounting kit.
What is the price of a DelVal Series 83 switch box?
The Series 83 price depends on the switch type (mechanical SPDT, inductive or proximity), the enclosure (IP65, IP67 or explosion proof), the cable entry thread and the mounting kit for your actuator. UEC quotes against those details.
How do I get the DelVal Series 83 catalogue and datasheet?
UEC sends the DelVal Series 83 catalogue and datasheet on request. Ask through the enquiry button or WhatsApp on this page and the Series 83 documents come with your quotation. Attach them to an instrument specification, and state the switch type, enclosure and cable entry thread in the enquiry.